Thermal resistance(AI)specification
Item | Thermal Resistance | |||
Input range | Pt100 | Pt1000 | Cu100 | Cu50 |
Resolution | 0.1℃ | |||
Input impedance | 6MΩ | |||
Input indication | LED light means normal, dark means break OFF | |||
Response time | 560ms/4 Channel, 880ms/8 Channel | |||
Digital input range | 16 bits, Code range: 0~32000 | |||
Precision | 0.1% F.S | |||
Power supply | MPU use internal power supply, Extension module use external power supply 24VDC ±10% 5VA | |||
Isolation mode | Opto-electric isolation, Non-isolation between Channel ,between analog and digital is opto-electric isolation | |||
Power consumption | 24VDC ±20%, 50mA(Max) |
Thermocouple(AI)specification
Item | Thermocuople input |
Input range | S,K, T, E, J ,B, N, R, Wre3/25, Wre5/26, [0-20]mV, [0-50]mV, [0-100]mV |
Resolution | 0.1℃ |
Input impedance | 6MΩ |
Max range | ±5V |
Input indication | LED light means normal, dark means break OFF |
Response time | 560ms/4 Channel, 880ms/8 Channel |
Digital input range | 16 bits, Code range: 0~32000 |
Precision | 0.1% F.S |
Power supply | MPU use internal power supply, Extension module use external power supply 24VDC ±10% 5VA |
Isolation mode | Opto-electric isolation, Non-isolation between Channel ,between analog and digital is opto-electric isolation |
Power consumption | 24VDC ±20%, 50mA(Max) |
Thermocouple and RTD Input wiring diagram